# Fronius 517: Change of master has taken place

**Series:** Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters

**Meaning:** A change of master occurred; possible transformer not connected, bridge short-circuit, or damaged intermediate-circuit detection.

## Likely causes
- Transformer not connected/plugged in
- Bridge short-circuit
- Damaged intermediate-circuit voltage detection

## Checks
- Check the causes listed; contact a Fronius-trained technician if it persists

## Parts implicated
none

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc

## Provenance
- [manual] p. 92 — "Change of master has taken place." — https://www.fronius.com/~/downloads/Solar%20Energy/Operating%20Instructions/42,0410,1089.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes