# Growatt 02: Over temperature

**Series:** Growatt SPF 3500/5000 ES off-grid solar inverter

**Meaning:** An internal component temperature exceeded about 100 °C.

## Likely causes
- Blocked airflow through the unit
- High ambient temperature
- Loose thermistor plug

## Checks
- Check whether airflow is blocked or ambient temperature too high
- Check whether the thermistor plug is loose

## Parts implicated
cooling, thermistor

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: none

## Provenance
- [manual] p. 39 — "Internal temperature of component is over 100℃. — Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. Check whether the thermistor plug is loose." — https://en.growatt.com/upload/file/SPF_3500-5000_ES_User_Manual_EN_202109.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes