# Growatt 04: Battery voltage / SOC is too low

**Series:** Growatt SPF 3500/5000 ES off-grid solar inverter

**Meaning:** The battery voltage or state of charge is too low for operation.

## Likely causes
- Battery discharged too deeply
- Battery not charging

## Checks
- Measure the battery voltage at the DC input
- Check battery SOC on the LCD for Li batteries
- Recharge the battery

## Parts implicated
battery

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: lithium_battery

## Provenance
- [manual] p. 39 — "The battery voltage/SOC is too low. — Measure battery voltage in DC input. Check battery SOC in LCD when use Li battery. Recharge the battery." — https://en.growatt.com/upload/file/SPF_3500-5000_ES_User_Manual_EN_202109.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes