# Growatt 05: Output short circuited

**Series:** Growatt SPF 3500/5000 ES off-grid solar inverter

**Meaning:** The AC output is short-circuited; the manual directs checking that the output wiring is connected correctly and removing the abnormal load before restarting.

## Likely causes
- Short circuit on the AC output
- Abnormal or faulty load

## Checks
- Check the output wiring is connected correctly
- Remove the abnormal load

## Parts implicated
AC wiring, load

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, grid_tie

## Provenance
- [manual] p. 39 — "Output short circuited. — Check if wiring is connected well and remove abnormal load." — https://en.growatt.com/upload/file/SPF_3500-5000_ES_User_Manual_EN_202109.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes