# SMA 301: Grid incident - ten-minute average grid voltage exceeded

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** The ten-minute average value of the grid voltage has left the permissible range because the grid voltage or grid impedance at the connection point is too high, so the inverter disconnects from the utility grid to maintain power quality. SMA's remedy is to verify the grid voltage during feed-in and to have the grid operator adjust the feed-in voltage or the monitored limits.

## Likely causes
- Sustained grid over-voltage over the ten-minute averaging window
- High grid impedance at the connection point

## Checks
- During feed-in, check whether the grid voltage at the connection point is permanently within the permissible range
- If local grid conditions are the cause, ask the grid operator to adjust the feed-in voltage or the monitored operating limits
- If the voltage is in range and the message persists, contact SMA Service

## Parts implicated
grid connection

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: grid_tie

## Provenance
- [manual] p. 84 — "Explanation: The ten-minute average value of the grid voltage is no longer within the permissible range. The grid voltage or grid impedance at the connection point is too high. The inverter disconnects from the utility grid to maintain power quality." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes