# SMA 3601: High leakage current - check generator

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** The leakage current of the inverter and the PV module is too high: there is a ground fault, a residual current or a malfunction. The inverter interrupts feed-in operation immediately after the threshold is exceeded and reconnects automatically once the fault is cleared; SMA's measure is to check the PV system for ground faults.

## Likely causes
- Ground fault in the PV array
- Residual current through damaged insulation
- Malfunction in the inverter's residual-current monitoring

## Checks
- Disconnect the inverter from voltage sources before working on the array
- Check the PV system for ground faults
- Confirm the fault is cleared before the inverter reconnects on its own

## Parts implicated
PV modules, DC cabling, RCD

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, pv_dc, grid_tie

## Provenance
- [manual] p. 89 — "Explanation: The leakage current of the inverter and the PV module is too high. There is a ground fault, a residual current or a malfunction." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes