# SMA 3801: Residual current too high - check generator (DC overcurrent)

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** Events 3801 and 3802 carry the event message 'Residual current too high / Check generator', and SMA's explanation is that there is an overcurrent at the DC input which makes the inverter briefly interrupt feed-in operation. The remedy given is to check that the PV array has been correctly rated and wired if the message appears frequently.

## Likely causes
- PV array over-rated for the inverter's DC input
- Incorrect string wiring or paralleling
- DC-side fault or short circuit

## Checks
- If the message is displayed frequently, ensure that the PV array has been correctly rated and wired
- Check the DC string wiring and the number of modules per string
- Contact SMA Service if the message persists after the array has been verified

## Parts implicated
PV strings, DC cabling

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: pv_dc, dc_bus

## Provenance
- [manual] p. 90 — "Explanation: Overcurrent at the DC input. The inverter briefly interrupts feed-in operation." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes