# SMA 401: Grid incident - stand-alone grid or large frequency change

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** Events 401 and 404 mean the inverter has disconnected from the utility grid because it detected a stand-alone (island) grid or a very large change in grid frequency. SMA asks the installer to establish that there is no power outage or work on the utility grid, to contact the grid operator if necessary, and to check the grid connection for significant short-term frequency fluctuations.

## Likely causes
- Utility grid outage or planned work on the grid
- Islanding / stand-alone grid condition at the site
- Large step change in grid frequency

## Checks
- Make sure there is no power outage or work being done on the utility grid and contact the grid operator if necessary
- Check the grid connection for significant short-term frequency fluctuations

## Parts implicated
grid connection

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: grid_tie

## Provenance
- [manual] p. 85 — "Explanation: The inverter has disconnected from the utility grid. A stand-alone grid or a very large change in the grid frequency was detected." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes