# SMA 507: Temperature AC frequency - power limited by high frequency

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** The inverter has reduced its power output because the grid frequency is too high, in order to support grid stability. SMA advises monitoring the frequency fluctuations and, where the message appears often, requesting the grid operator's approval to change the operating parameters.

## Likely causes
- Grid frequency above the permissible range
- Frequent grid frequency fluctuations at the connection point

## Checks
- Check the grid frequency and observe how often fluctuations occur
- If the message appears often, ask the grid operator to approve a change of the operating parameters
- Discuss any approved change with SMA Service

## Parts implicated
grid connection

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: grid_tie

## Provenance
- [manual] p. 86 — "Explanation: The inverter has reduced its power due to a too-high grid frequency to ensure grid stability." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes