# SMA 601: Grid incident - DC proportion in grid current too high

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** The inverter has detected an excessively high proportion of direct current in the grid current and has disconnected from the utility grid. SMA tells the installer to check the grid connection for direct current and, if the message appears frequently, to ask the grid operator whether the monitoring threshold on the inverter may be raised.

## Likely causes
- Direct current component on the AC side of the installation
- Fault in the inverter's output stage or current control
- Monitoring threshold not suited to the local grid

## Checks
- Check the grid connection for direct current
- If the message appears frequently, contact the grid operator and ask whether the monitoring threshold can be raised

## Parts implicated
AC wiring, inverter

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: grid_tie, dc_bus

## Provenance
- [manual] p. 86 — "Explanation: The inverter has detected an excessively high proportion of direct current in the grid current." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes