# SMA 6502: Self-diagnosis - overtemperature

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** Events 6501, 6502 and 6509 all mean the inverter has switched off because of excessive temperature. SMA's measures are to clean the cooling fins and air ducts with a soft brush, ensure the enclosure is sufficiently ventilated, keep it out of direct solar irradiation and make sure the maximum ambient temperature is not exceeded.

## Likely causes
- Blocked or dirty cooling fins and air ducts
- Insufficient ventilation around the enclosure
- Ambient temperature above the permitted maximum
- Direct solar irradiation on the inverter

## Checks
- Clean the cooling fins on the rear of the enclosure and the air ducts on the top using a soft brush
- Ensure that the inverter has sufficient ventilation
- Ensure that the inverter is not exposed to direct solar irradiation
- Ensure the maximum ambient temperature is not exceeded

## Parts implicated
heat sink, cooling

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: none

## Provenance
- [manual] p. 93 — "Explanation: The inverter has switched off due to excessive temperature." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: no