# SMA 6902: Self-diagnosis - input A / input B defective (polarity error)

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** Events 6801 and 6802 are reported as 'Self-diagnosis > Input A defective' and events 6901 and 6902 as 'Self-diagnosis > Input B defective'; the explanation SMA gives for all four is a polarity error on the inverter. The measures are to check whether a string is connected to input A (or B) and to contact Service.

## Likely causes
- PV string connected with reversed polarity to the DC input
- No string connected to the input although one is configured
- Input-stage fault on the DC input

## Checks
- Check whether a string is connected to the input and that its polarity is correct
- Contact SMA Service if the message persists

## Parts implicated
PV strings, DC input

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: pv_dc, dc_bus

## Provenance
- [manual] p. 96 — "Explanation: Polarity error on the inverter." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes