# SMA 701: Frequency not permitted - check parameter

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** The grid frequency is not within the permissible range, so the inverter has disconnected from the utility grid. Unlike event 501, SMA additionally asks the installer to check the AC wiring between the inverter and the feed-in meter, and to get the grid operator's approval before changing operating parameters.

## Likely causes
- Grid frequency outside the permissible range
- AC wiring fault between the inverter and the feed-in meter
- Operating parameters not matching the local grid code

## Checks
- Check the AC wiring from the inverter to the feed-in meter
- Check the grid frequency and observe how often fluctuations occur
- If the message appears often, ask the grid operator to approve a change of the operating parameters

## Parts implicated
AC wiring, feed-in meter

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.