# SMA 8708: Timeout in communication for active power limitation

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** Communication to the system control is absent, so the inverter falls back either to the last received values or to a fixed percentage of its nominal power for active power limitation. SMA asks for the connection to the system manager to be checked for damage and pulled plugs.

## Likely causes
- System manager offline or unreachable
- Damaged or disconnected communication cable
- Network fault between inverter and system manager

## Checks
- Ensure that the connection to the system manager (e.g. Sunny Home Manager) is intact
- Check that no cables are damaged and no plugs have been pulled
- Confirm the fall-back active power limit is acceptable until communication is restored

## Parts implicated
communication, system manager

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: none

## Provenance
- [manual] p. 98 — "Explanation: Communication to the system control absent. Depending on the fallback setting, either the last received values will be retained or the active power will be limited to the set percentage value of the inverter nominal power." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: no