# SMA 8709: Timeout in communication for reactive power / cos phi setpoint

**Series:** SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

**Meaning:** Event 8709 is 'Timeout in communication for reactive power setpoint' and event 8710 is 'Timeout in communication for cos phi setpoint'. SMA's explanation is that communication to the system control is absent, so the inverter falls back to the last received values or to the configured set value, and it asks for the connection to the system manager (e.g. Sunny Home Manager) to be checked for damage and pulled plugs.

## Likely causes
- System manager offline or unreachable
- Damaged or disconnected communication cable
- Network fault between inverter and system manager

## Checks
- Ensure that the connection to the system manager is intact
- Check that no cables are damaged and no plugs have been pulled
- Confirm the fall-back setpoint with the grid operator if the message persists

## Parts implicated
communication, system manager

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: none

## Provenance
- [manual] p. 98 — "Explanation: Communication to the system control absent." — https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: no