# SolarEdge 18x6F: AC current surge (three-phase)

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** A three-phase inverter logged an AC current surge (the table lists this code group as 18x6F/70/71 for AC Current Surge and Vac surge). Check the AC connection and ask the grid operator about surge sources near the site.

## Likely causes
- AC voltage/current surge on the grid
- Irregular load or large surge source near the site

## Checks
- Check the AC connection to the inverter
- Ask the grid operator whether a large surge source or irregular load exists near the site
- If the grid is clean, contact SolarEdge Support

## Parts implicated
AC wiring

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: grid_tie

## Provenance
- [manual] p. 1 — "AC Current Surge Vac surge Ground current surge." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes