# SolarEdge 18x7B: MainError (grid measurements out of range)

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** The inverter's grid measurements are out of range. The addendum says to contact the grid operator.

## Likely causes
- Grid voltage or frequency outside the measurable range
- Grid supply fault or measurement fault

## Checks
- Check the AC supply at the main connection point
- Contact the grid operator with the error details

## Parts implicated
none

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: grid_tie

## Provenance
- [manual] p. 6 — "MainError Grid measurements are out of range. Contact the grid operator." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes
