# SolarEdge 2x19: Isolation fault

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** The inverter detected that the PV array is not properly isolated from earth. The addendum says to check the PV installation for isolation problems and ground leakage, and that only a certified PV installer may fix the faulty string before it is reconnected.

## Likely causes
- Damaged module insulation or backsheet
- Damaged DC cable, connector or junction
- Water ingress or soiling creating a path to earth

## Checks
- Check the PV installation for isolation problems and ground leakage
- Use the inverter's isolation status screen (R Iso) to find the leaking string
- Leave the faulty string disconnected until a certified PV installer repairs it

## Parts implicated
PV modules, DC cabling, power optimizers

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, pv_dc

## Provenance
- [manual] p. 3 — "Isolation Fault PV solar array is not properly isolated from ground earth." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes