# SolarEdge 2x86: DSP1-DSP2 VDC difference max

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** The two DSP controllers inside the inverter measured a DC voltage difference beyond the allowed maximum, which points to a hardware or sensing fault. The addendum directs you to contact SolarEdge support.

## Likely causes
- DC voltage sensing or divider fault
- Power-board or DSP hardware fault

## Checks
- Note the code and serial number
- Contact SolarEdge support

## Parts implicated
inverter, DC bus

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, dc_bus, pv_dc

## Provenance
- [manual] p. 7 — "DSP1- DSP2 VDC difference max Contact SolarEdge support." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes