# SolarEdge 2xA: Ground current / RCD trip

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** A residual-current (ground-fault) event was detected. The addendum explains that ground faults may occur when insulation to ground is insufficient, warns of electric shock hazard inside the cover, and gives a string-by-string procedure that only a qualified technician may carry out.

## Likely causes
- Damaged or degraded module insulation
- Damaged DC string cable or connector
- Moisture or soiling creating a leakage path to earth

## Checks
- Turn the inverter ON/OFF switch to OFF and wait five minutes for the input capacitors to discharge
- Disconnect the AC breaker and the DC inputs
- Reconnect one DC string at a time until the error reappears to identify the faulty string
- Do not reconnect a string with a ground fault; a certified installer must repair it first

## Parts implicated
PV modules, DC cabling, RCD

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, pv_dc

## Provenance
- [manual] p. 2 — "Ground Current - RCD Ground faults may occur due to insufficient insulation to the ground." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes