# SolarEdge 2xF: DC voltage too high (surge)

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** The DC input voltage from the PV array exceeded the inverter's limit, usually as a surge. SolarEdge notes its system normally eliminates DC over-voltage errors; if the fault persists, switch the inverter off, wait five minutes and check which string is malfunctioning and its connections.

## Likely causes
- PV string too long for the inverter's DC input range
- Power optimizer failure or bypassed optimizer
- DC surge or loose string connection

## Checks
- Turn the inverter ON/OFF switch OFF and wait five minutes
- Check whether the LCD shows the expected low safety voltage (about 1 V per optimizer)
- Identify the malfunctioning string and recheck its connections to the inverter
- Follow the Power Optimizer Troubleshooting section of the installation guide

## Parts implicated
PV strings, power optimizers, DC cabling

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, pv_dc

## Provenance
- [manual] p. 2 — "DC Voltage Too High (surge) The SolarEdge system normally eliminates DC overvoltage errors." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes