# SolarEdge 8x2B: Ground current / RCD trip (three-phase)

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** A three-phase inverter detected a ground-fault current (codes 8x2B/8x2C/8x39 share this row). The addendum attributes it to insufficient insulation to ground and requires the string-by-string isolation procedure by a qualified technician.

## Likely causes
- Damaged or degraded module insulation
- Damaged DC string cable or connector
- Moisture creating a leakage path to earth

## Checks
- Switch the inverter off, wait five minutes, then disconnect AC and DC
- Reconnect DC strings one at a time until the fault reappears
- Leave the faulty string disconnected for a certified installer to repair

## Parts implicated
PV modules, DC cabling, RCD

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, grid_tie, pv_dc

## Provenance
- [manual] p. 2 — "Ground Current - RCD Ground faults may occur due to insufficient insulation to the ground." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes