# SolarEdge 8x36: Islanding - active

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** The inverter detected an active islanding condition (AC grid voltage malfunction) and stopped producing. It restarts after the reconnection time when AC voltage returns; if the problem persists, consult the grid operator.

## Likely causes
- Grid outage or voltage malfunction
- Upstream protection or breaker open

## Checks
- Check the grid supply at the main connection point
- Wait for the reconnection time after the grid returns
- Consult the grid operator if it persists

## Parts implicated
none

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, grid_tie

## Provenance
- [manual] p. 4 — "Islanding - Active AC grid voltage malfunction. When AC voltage returns the inverter should restart after the reconnection time." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: no