# SolarEdge 8x42: AC voltage too high (line 1/2/3, three-phase)

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** The AC grid voltage on one line exceeded the country limit (codes 8x42/8x43/8x44). The addendum says to verify the country setting, consult the grid operator and, if local authorities permit, change the grid protection values.

## Likely causes
- Grid over-voltage above the country limit
- Wrong country/grid-code setting

## Checks
- Verify the inverter is set to the correct country
- Consult the grid operator
- Change grid protection values only if permitted by local authorities

## Parts implicated
AC wiring

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: grid_tie

## Provenance
- [manual] p. 4 — "AC Voltage Too High Line 1/2/3 Verify that the inverter is set to the correct country." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes