# SolarEdge 8x46: UDC min (DC input under-voltage)

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** The DC input voltage (UDC) fell below the inverter's minimum, so it cannot operate. The addendum has no field repair and directs you to contact SolarEdge support.

## Likely causes
- String voltage below the inverter's minimum
- Optimizer or string wiring fault
- Low irradiance or a disconnected string

## Checks
- Check the DC voltage and string count on the status screen
- Confirm all strings are connected and producing
- Contact SolarEdge support if the voltage is low in full sun

## Parts implicated
PV strings, power optimizers

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, pv_dc

## Provenance
- [manual] p. 5 — "UDC Min Contact SolarEdge support." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes