# SolarEdge 8x51: RCD current surge

**Series:** SolarEdge single-phase and three-phase inverters (Europe & APAC)

**Meaning:** A residual-current surge was detected on the DC side, which usually means a ground-fault/insulation problem in the PV array. SolarEdge points to its isolation-fault troubleshooting application note and to support.

## Likely causes
- Insufficient insulation to ground in the PV array
- Damaged DC cable or connector
- Water ingress in a junction or optimizer

## Checks
- Follow the isolation-fault troubleshooting application note
- Isolate and test string by string to locate the leakage
- Contact SolarEdge support if the fault persists

## Parts implicated
PV modules, DC cabling, RCD

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, pv_dc

## Provenance
- [manual] p. 4 — "RCD Current Surge Refer to: www.solaredge.com/files/pdfs/application_note_ isolation_fault_troubleshooting.pdf Contact SolarEdge support." — https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (retrieved 2026-11-21)

- Confidence: verified
- Verified by: manual
- Requires qualified installer: yes