# Victron Err 114: CPU temperature too high

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The charger CPU is too hot; the error resets after the CPU cools. Persistent error suggests a faulty controller.

## Likely causes
- High ambient temperature
- Obstructed air inlet/outlet
- Poor mounting with insufficient cooling

## Checks
- Check ambient temperature and clear obstructions near air inlets/outlets
- Check the manual's mounting requirements for cooling
- Replace the controller if it persists

## Parts implicated
cooling

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: none

## Provenance
- [vendor_kb] § Err 114 - CPU temperature too high — "This error will reset after the CPU has cooled down." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes