# Victron Err 116: Calibration data lost

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The unit's calibration data is missing or lost. If it is the active error the unit is faulty; if only in history while the unit works normally it can be ignored.

## Likely causes
- Faulty unit
- Reverting SmartSolar firmware from v1.4x to older firmware
- Factory first-boot history entry

## Checks
- If active and the unit is not working, contact the dealer for replacement
- If only in history and the unit works, ignore safely
- Re-install v1.4x firmware after an attempted downgrade

## Parts implicated
charge controller

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: none

## Provenance
- [vendor_kb] § Err 116 - Calibration data lost — "If the unit does not work and error 116 pops up as the active error the unit is faulty, contact your dealer for a replacement." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: vendor
- Verified by: vendor_kb
- Requires qualified installer: yes