# Victron Err 18: Controller over-current

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** Current on the battery terminals exceeded the controller limit. It usually auto-resets; if not, the unit can be power-cycled.

## Likely causes
- Large load switched on the battery side
- Sudden irradiance change causing a temporary power spike
- Inverter AC output overloaded

## Checks
- Allow the controller to cool and provide adequate ventilation
- Reduce inverter load
- If it persists, isolate all power, wait 3 minutes, then repower

## Parts implicated
charge controller

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: lithium_battery

## Provenance
- [vendor_kb] § Err 18 - Controller over-current — "This error will auto-reset." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes