# Victron Err 20: Maximum Bulk-time exceeded

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The charger did not reach absorption voltage within the bulk-time limit (10 hours on Skylla AC chargers), so it stopped to protect against a shorted cell. On older solar chargers, updating firmware removes the obsolete feature.

## Likely causes
- Shorted or failing cell
- Battery not reaching absorption voltage within the time limit
- Outdated charger firmware (solar chargers)

## Checks
- Update solar charger firmware to latest, then reset to factory defaults and reconfigure
- For AC chargers, test the battery for a shorted cell

## Parts implicated
battery, firmware

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: pv_dc

## Provenance
- [vendor_kb] § Err 20 - Maximum Bulk-time exceeded — "Solar Chargers The maximum bulk time protection is a feature that was in the chargers when they were just released (2015 or earlier) and later the feature was removed." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: no