# Victron Err 29: Over-charge protection

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The charger disconnected the battery to protect it from over-charging; it resets once battery voltage drops below float.

## Likely causes
- Oversized PV array wired with too many panels in series
- Battery settings (absorption/float) not matching the installation
- Another charger raising the battery voltage

## Checks
- Check PV array configuration and re-wire panels in parallel to reduce voltage if needed
- Verify absorption and float voltage settings match the battery
- Check for other chargers on the battery

## Parts implicated
battery, PV array

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: lithium_battery, pv_dc

## Provenance
- [vendor_kb] § Err 29 - Over-Charge protection — "This error will auto-reset once the battery voltage drops below the float voltage." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes