# Victron Err 3: Remote temperature sensor failure

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The remote temperature sensor reading is invalid, usually because the T-sense connector is wired to the battery terminal instead of a temperature sensor.

## Likely causes
- T-sense connector connected to BAT+ or BAT- instead of a temperature sensor
- Faulty sensor or wiring

## Checks
- Check the T-sense connector is on a temperature sensor, not a battery terminal
- Reconnect correctly and confirm the error clears

## Parts implicated
temperature sensor

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: lithium_battery

## Provenance
- [vendor_kb] § Err 3, Err 4 - Remote temperature sensor failure — "Check if the T-sense connector is properly connected to a remote temperature sensor." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes