# Victron Err 33: PV over-voltage

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The PV open-circuit voltage is critical for this charger (too high for its rating); the error resets once PV voltage drops to a safe level.

## Likely causes
- PV array open-circuit voltage too high for the charger
- Too many panels in series

## Checks
- Check the PV array configuration against the charger's max PV voltage
- Re-organise panels (fewer in series) if required

## Parts implicated
PV array

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, pv_dc

## Provenance
- [vendor_kb] § Err 33 - PV over-voltage — "This error will auto-reset after PV-voltage has dropped to safe limit." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes