# Victron Err 38: PV input shutdown (battery over-charge protection)

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The PV input was internally shorted to protect the battery from over-charging. Check firmware and the battery voltage setting before other troubleshooting.

## Likely causes
- Battery voltage (12/24/36/48 V) set incorrectly
- Another device on the battery configured to a higher voltage
- Outdated firmware

## Checks
- Update to the latest firmware
- Verify the battery voltage setting in VictronConnect
- Disconnect panels then battery, wait 3 minutes, reconnect battery then panels

## Parts implicated
battery, PV input

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, lithium_battery, pv_dc

## Provenance
- [vendor_kb] § Err 38, Err 39 and Err 80 to Err 87 - PV Input shutdown — "When these errors show, the PV Input is internally shorted in order to protect the battery from over-charging." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes