# Victron Err 39: PV input shutdown (over-voltage, auto-recover)

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The PV input was internally shorted to protect the battery from over-charging; the charger resumes automatically once battery voltage drops below its maximum voltage setting.

## Likely causes
- Battery voltage setting incorrect
- Another device on the battery set to a higher voltage
- Outdated firmware

## Checks
- Update firmware
- Verify battery voltage settings
- Confirm the error clears as battery voltage falls

## Parts implicated
battery, PV input

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, lithium_battery, pv_dc

## Provenance
- [vendor_kb] § Err 38, Err 39 and Err 80 to Err 87 - PV Input shutdown — "When these errors show, the PV Input is internally shorted in order to protect the battery from over-charging." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes