# Victron Err 41: PV isolation failure

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The PV array's isolation resistance is too low. On inverters the unit restarts once resolved; solar chargers remain operational but keep the warning until cleared.

## Likely causes
- Damaged PV cabling or connectors
- Panel insulation fault
- Moisture ingress

## Checks
- Check PV array cabling and panel isolation
- On inverters, disconnect the PV array with the PV switch to resume AC operation

## Parts implicated
PV cabling, panels

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, pv_dc

## Provenance
- [vendor_kb] § Err 41 - PV isolation failure — "PV panel isolation resistance too low." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes