# Victron Err 43: Ground fault detected

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The voltage between Neutral and Ground is too high. On grid-connected systems this usually means the installation ground is missing/incorrect or Line and Neutral are swapped; on island systems the ground relay may be damaged. It does not auto-reset.

## Likely causes
- Missing or incorrectly connected ground wire
- Line and Neutral swapped in the installation
- Damaged ground relay (island operation)

## Checks
- Check the installation ground and Line/Neutral wiring
- Restart the unit with the power switch after correcting the wiring

## Parts implicated
ground wiring, ground relay

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_arc, grid_tie

## Provenance
- [vendor_kb] § Err 43 - Ground fault detected — "The voltage difference between Neutral and Ground is too high." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes