# Victron Err 5: Remote temperature sensor failure (connection lost)

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The charger has lost connection to the remote temperature sensor it was previously reading.

## Likely causes
- Loose or disconnected T-sense wiring
- Failed temperature sensor

## Checks
- Check the T-sense connector and cable
- Reconnect and confirm the reading returns in VictronConnect

## Parts implicated
temperature sensor

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: none

## Provenance
- [vendor_kb] § Err 5 - Remote temperature sensor failure (connection lost) — "Check if the T-sense connector is properly connected to a remote temperature sensor. This error will not auto-reset." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: no