# Victron Err 68: Network misconfigured

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The charger detects multiple conflicting network sources (VE.Can and VE.Direct) with the same priority sending the same information.

## Likely causes
- Both VE.Direct and VE.Can connected at the same time
- Firmware older than v1.48 (SmartSolar VE.Direct)

## Checks
- Update firmware
- Remove one of the two cables (VE.Direct or VE.Can)

## Parts implicated
communication cabling

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: none

## Provenance
- [vendor_kb] § Err 68 - Network misconfigured — "Applies to SmartSolar/BlueSolar MPPTs VE.Can (FW version v1.04 or higher) and SmartSolar VE.Direct MPPTs (FW version v1.47)." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: vendor
- Verified by: vendor_kb
- Requires qualified installer: yes