# Victron Err 69: Network misconfigured (phase/frequency)

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** Units on the same CAN bus have different system configurations (single/three-phase or 50/60 Hz). Units stay off until the configuration is fixed.

## Likely causes
- Mismatched single/three-phase setting
- Mismatched 50/60 Hz setting

## Checks
- Set all units to the same phase configuration and frequency

## Parts implicated
none

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_bus, grid_tie

## Provenance
- [vendor_kb] § Err 69 - Network misconfigured — "Applies to Inverter RS and Multi RS models." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: vendor
- Verified by: vendor_kb
- Requires qualified installer: yes