# Victron Err 76: Network incomplete

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The networked inverters shut down because there are insufficient units to run the configured system.

## Likely causes
- A required unit not powered on
- CAN interface cables not connected properly

## Checks
- Check all required units are powered on
- Check the CAN interface cable connections

## Parts implicated
CAN cabling

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: none

## Provenance
- [vendor_kb] § Err 76 - Network incomplete — "Applies to Inverter RS and Multi RS models." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: vendor
- Verified by: vendor_kb
- Requires qualified installer: yes