# Victron Info 66: Incompatible device

**Series:** Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

**Meaning:** The controller is paralleled to another controller with different settings or a different charge algorithm, or MPPTs are on VE.Smart networking while connected to a GX device.

## Likely causes
- Mismatched settings or charge algorithms between parallel controllers
- VE.Smart networking enabled while connected to a GX device

## Checks
- Match all settings and update firmware on all chargers
- Disable VE.Smart networking and use DVCC on the GX device instead

## Parts implicated
none

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: pv_dc

## Provenance
- [vendor_kb] § Information 66 - Incompatible device — "The controller is being paralleled to another controller that has different settings and/or a different charge algorithm." — https://www.victronenergy.com/live/mppt-error-codes (retrieved 2026-11-21)

- Confidence: vendor
- Verified by: vendor_kb
- Requires qualified installer: no