# Victron VE.Bus Error 12: Config mismatch with 2nd MCU

**Series:** Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger)

**Meaning:** Two microcontrollers in the unit hold mismatched configuration that could not be reconciled automatically.

## Likely causes
- Configuration mismatch between the unit's two MCUs

## Checks
- Connect to VEConfigure 3, verify/correct settings, and send 'all settings'

## Parts implicated
configuration

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_bus

## Provenance
- [vendor_kb] § Error 12 - Config mismatch with 2nd mcu — "Some Multi models (e.g." — https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: no