# Victron VE.Bus Error 17: Phase master missing

**Series:** Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger)

**Meaning:** Shown on slaves when communication with the phase-master timed out. Only occurs with multiple devices per phase.

## Likely causes
- VE.Bus cabling issue
- Blown DC fuse on a unit
- Outdated firmware/Assistants

## Checks
- Check network cable sockets and replace cables if needed
- Check DC fuses on all units
- Update inverter/charger firmware, Assistants, and GX device firmware

## Parts implicated
VE.Bus cabling, DC fuse, firmware

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_bus, grid_tie, lithium_battery

## Provenance
- [vendor_kb] § Error 17 - Phase master missing — "Error 17 shows on slaves (only)." — https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes