# Victron VE.Bus Error 19: Slave does not have AC input

**Series:** Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger)

**Meaning:** A synchronised slave has no AC input (e.g. a generator is only connected to one unit).

## Likely causes
- AC input only connected to one of the synchronised inverter/chargers

## Checks
- Connect AC input to all units, or disable 'Switch as Group' in VE.Bus System Configurator (not possible in ESS)

## Parts implicated
AC-in wiring

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_bus, grid_tie

## Provenance
- [vendor_kb] § Error 19 - Slave does not have AC input! — "Common cause - System is configured with multiple synchronised inverter/chargers but AC input (e.g." — https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes