# Victron VE.Bus Error 25: Incompatible VE.Bus configuration

**Series:** Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger)

**Meaning:** The VE.Bus configuration is not allowed, usually from mismatched firmware or incompatible devices (compatibility ID).

## Likely causes
- Different firmware versions across devices
- Incompatible compatibility IDs

## Checks
- Update all devices to the same firmware
- Check the compatibility IDs on the unit stickers match the rules

## Parts implicated
firmware

## Safety
Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. This page is a diagnostic reference, not step-by-step work instructions. Isolate and verify de-energised before any physical check, and escalate to a qualified installer/electrician for anything beyond reading the display or checking a connector on isolated equipment.

Safety flags: dc_bus

## Provenance
- [vendor_kb] § Error 25 - Incompatible VE.Bus configuration — "The VE.Bus configuration as configured is not allowed." — https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes (retrieved 2026-11-21)

- Confidence: verified
- Verified by: vendor_kb
- Requires qualified installer: yes