Growatt SPF 3500/5000 ES off-grid solar inverter
Growatt 02: Over temperature
Quick answerGrowatt 02 means An internal component temperature exceeded about 100 °C..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
An internal component temperature exceeded about 100 °C.
Likely causes
- Blocked airflow through the unit
- High ambient temperature
- Loose thermistor plug
What to check
- Check whether airflow is blocked or ambient temperature too high
- Check whether the thermistor plug is loose
Parts implicated
coolingthermistor
Sources (verbatim):
- https://en.growatt.com/upload/file/SPF_3500-5000_ES_User_Manual_EN_202109.pdf (manual, retrieved 2026-11-21) p. 39
“Internal temperature of component is over 100℃. — Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. Check whether the thermistor plug is loose.”
Paraphrased; verify against the manual for your exact model and serial number.