Fronius fault codes
48 verified codes, each with a cited source, likely causes, checks, parts and safety notes.
| Code | Meaning | Series | Access |
|---|---|---|---|
| 101 | Grid voltage not within admissible range | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 104 | Grid frequency not within admissible range | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 107 | No AC grid detected | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 108 | Islanding detected | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 221 | Grid voltage L1/N exceeds admissible limits | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 222 | Grid voltage L1/N below admissible limits | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 223 | Grid voltage L2/N exceeds admissible limits | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 224 | Grid voltage L2/N below admissible limits | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 225 | No grid voltage detected | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 301 | Overcurrent (AC) | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 302 | Overcurrent (DC) | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 303 | Over-temperature AC side | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 304 | Over-temperature DC side | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 306 | POWER LOW | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 307 | DC LOW | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 401 | No internal communication with power stage set | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 402 | Communication with EEPROM not possible | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 403 | EEPROM faulty | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 406 | Temperature sensor(s) defective | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 407 | Temperature sensor at cooling element defective | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 408 | Direct current feed in | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 409 | No +15V supply for control electronics | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 410 | Service plug not in original position | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 412 | Fixed voltage selected instead of MPP operation | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 413 | Control problems | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 414 | EEPROM faulty (memory deleted) | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 417 | Two power stage sets with the same PCB number | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 419 | Identical software serial number on power stage sets | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 421 | PCB number set incorrectly | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 425 | Communication with power stage set not possible | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 434 | Ground fault detected | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 446 | Internal communication error with NL-MON plug-in card | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 447 | GFDI stopped grid monitoring | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 448 | Neutral conductor N not connected | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 501 | One of the two fans is defective | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 504 | No Solar Net communication possible | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | self-check |
| 505 | EEPROM faulty (setup data lost) | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 506 | EEPROM faulty (total data lost) | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 507 | EEPROM faulty (day/year data lost) | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 508 | Inverter address incorrect | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | self-check |
| 509 | 24h no feed in | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | self-check |
| 510 | EEPROM faulty (SMS settings defaulted) | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 511 | EEPROM faulty (sensor card defaulted) | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 512 | Too many power stage sets in the system | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 514 | No communication with one power stage set | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 515 | Faulty plug connections | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 516 | Status code present for one power stage set | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
| 517 | Change of master has taken place | Fronius IG / IG Plus (IG 15-60, IG 2000/3000/4000/5100) grid-tied inverters | qualified |
Independent and unofficial. Compiled from public Fronius documentation. Verify against the manual for your exact model.