Victron fault codes
74 verified codes, each with a cited source, likely causes, checks, parts and safety notes.
| Code | Meaning | Series | Access |
|---|---|---|---|
| Err 1 | Battery temperature too high | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 11 | Battery high ripple voltage | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 114 | CPU temperature too high | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 116 | Calibration data lost | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 117 | Incompatible firmware | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | self-check |
| Err 119 | Settings data lost | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 121 | Tester fail | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 14 | Battery low temperature | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 17 | Controller overheated despite reduced output current | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 18 | Controller over-current | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 2 | Battery voltage too high | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 20 | Maximum Bulk-time exceeded | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | self-check |
| Err 200 | Internal DC voltage error | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 201 | Internal DC voltage measurement error | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 202 | Internal GFCI sensor error | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 203 | Internal supply voltage error | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 21 | Current sensor issue | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 22 | Internal temperature sensor failure | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 24 | Fan failure | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 26 | Terminal overheated | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 27 | Charger short circuit | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 28 | Power stage issue | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 29 | Over-charge protection | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 3 | Remote temperature sensor failure | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 33 | PV over-voltage | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 34 | PV over-current | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 35 | PV over-power | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 38 | PV input shutdown (battery over-charge protection) | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 39 | PV input shutdown (over-voltage, auto-recover) | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 40 | PV input failed to shutdown | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 41 | PV isolation failure | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 42 | PV isolation failure (ground leakage) | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 43 | Ground fault detected | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 5 | Remote temperature sensor failure (connection lost) | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | self-check |
| Err 50 | Inverter overload / peak current | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 51 | Inverter temperature too high | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 52 | Inverter peak current | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 53 | Inverter output voltage (low) | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 54 | Inverter output voltage (low) | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 55 | Inverter self test failed | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 57 | Inverter AC voltage on output | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 59 | ACIN1 relay test fault | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 6 | Remote battery voltage sense failure | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 67 | BMS connection lost | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 68 | Network misconfigured | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 69 | Network misconfigured (phase/frequency) | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 72 | Phase rotation | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 76 | Network incomplete | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | qualified |
| Err 8 | Remote battery voltage sense failure (connection lost) | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | self-check |
| Info 65 | Communication warning (parallel controller) | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | self-check |
| Info 66 | Incompatible device | Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC | self-check |
| VE.Bus Error 1 | Device switched off because another phase switched off | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 10 | System time synchronisation problem | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | self-check |
| VE.Bus Error 11 | Relay test fault (installation or relay failure) | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 12 | Config mismatch with 2nd MCU | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | self-check |
| VE.Bus Error 128 | Connect prevented by failing relay test | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 14 | Device cannot transmit data | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 15 | VE.Bus combination error | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 16 | VE.Bus dongle is missing | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | self-check |
| VE.Bus Error 17 | Phase master missing | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 18 | AC over-voltage on switched-off slave output | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 19 | Slave does not have AC input | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 2 | New and old MK2 protocol mixed | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 20 | Configuration mismatch | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | self-check |
| VE.Bus Error 22 | Device cannot function as a slave | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 24 | Switch-over system protection initiated | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 25 | Incompatible VE.Bus configuration | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 26 | Internal error | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 3 | Unexpected number of devices found | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 4 | No other device found | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | self-check |
| VE.Bus Error 5 | Overvoltage on AC out | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 6 | Error in DDC program (Assistant) | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 7 | External device connected, Assistant required | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
| VE.Bus Error 8 | Ground relay test failed | Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger) | qualified |
Independent and unofficial. Compiled from public Victron documentation. Verify against the manual for your exact model.