Isolation / ground fault on a solar system

An isolation or ground fault means leakage current is flowing where it should not. This is a safety condition: find the code, isolate, and escalate.

Solar inverters and charge controllers continuously measure isolation resistance between the PV array and earth. When that resistance drops, or when leakage current exceeds a limit, the unit raises an isolation or ground fault and — in most cases — stops exporting.

Which codes report it

  • Victron: Err 41 / Err 42 (PV isolation failure / ground leakage above 30 mA) and Err 43 (ground fault — Neutral/Ground voltage too high).
  • SolarEdge: the isolation fault code (a low isolation resistance reading) appears in the monitoring portal; the exact string varies by firmware.
  • Fronius: ground-fault / insulation-fault messages appear in the service messages for the specific inverter.

Why it is dangerous

An isolation fault means the array or its cabling is leaking current to earth. Touching the frame, rails, or connectors can complete a circuit. A ground fault where Line and Neutral or the ground bond is wrong is equally serious on the AC side.

What to do

  1. Read the exact code and note it with the source link.
  2. Isolate the PV array with the DC/array switch (where fitted) and isolate the AC supply.
  3. Do not megger or test a live array, and do not open energised DC enclosures.
  4. Escalate to a qualified installer/electrician to locate damaged cabling, connectors, or panel insulation.

This page is a diagnostic reference, not work instructions. Always escalate isolation and ground faults to a qualified installer.

FAQ

What causes an isolation fault on a solar system?

Damaged PV cabling or connectors, panel insulation faults, and moisture ingress are the common causes. The inverter detects low isolation resistance or excess leakage current and stops.

Is an isolation fault dangerous?

Yes. It means current is leaking where it should not, so exposed metal can become live. Isolate and escalate to a qualified installer.

Can I keep the system running with a ground fault?

No. Keep it isolated until a qualified installer finds and fixes the fault.

Independent and unofficial. General diagnostic guidance, not a substitute for the manual for your exact model.